DC Energy Display
Product Code: 023-4346-0
Description
- Displays 12 or 24 volts
- Displays up to 500 amps
- Displays energy used and remaining for up to 3,000 amp-hour capacity
- Monitor voltage on up to three separate banks of batteries
- Monitors Charge / Discharge Amperage
- Monitors Total Energy: Amp-Hours or Percent of Charge
- Alarms: High / low voltage and low amp-Hours remaining
- 3 year warranty
Warranty | 3 Years |
Weight | .25 lbs |
Power Supply | 9.5 to 33.0 VDC, .018 amps nominal |
Operating Temperature | 32 to 122 F (0 to 50 C) |
Accuracy | Better than +/- 0.1 VDC for Volts and 1% +/- 1 Amp for Amps |
Volts Range | 9.5 to 33.0 VDC |
Amps Range | -500 to +500 Amps (Applies to Bank 1 Only) |
Capacity Remaining Range | -0 to +100% (Applies to Bank 1 Only) |
Shunt | 500 Amp, 50 mV |
NMEA 0183 | $IIXDR, V; $IIXDRA, A; $IIXDR,G |
DC Amps | yes |
Digital Display | yes |
Watertight | yes |
DC Volts | yes |
Amp Hours | yes |
Amp-Hours Range | -500 to +500 Amps (Applies to Bank 1 Only) |
Alarms | High, Low Voltage & Low Amp-Hours |
The DCE provides accurate low cost instrumentation for 3 banks of
batteries between 9.5 and 33 volts. The unit displays voltage for three
banks and amps or amp-hours for the house bank. It tracks all current
entering and leaving the house bank and applies Peukert's and efficiency
factors. Low and High voltage alarms and Low Amo-Hours Remaining alarms
can be set on the house bank. When activated, the built-in 85 dB alarm
will sound and the display will flash. The DCE outputs NMEA 0183 serial
data or the data line can be programmed as an external alarm output or
as a charger on-off control. The DCE comes complete with a precision 500
amp shunt and is designed to work with 50-500 amp 50 mV shunts.